Unable to compare with previous version: Unable to find version history at http://example.org (Problem #1 with package-list.json at http://example.org: Not Found)
IPA Comparison:
n/a
IPS Comparison:
n/a
Validation Flags:
On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings
INFORMATION: StructureDefinition/Bundle-twngs: StructureDefinition.snapshot.element[4].binding.extension[0]: The extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.2.0 is deprecated (1 uses)
INFORMATION: StructureDefinition/Patient-twngs: StructureDefinition.snapshot.element[28].type[0].extension[1]: The extension http://hl7.org/fhir/StructureDefinition/regex|5.2.0 is deprecated with the note: 'This was deprecated in favor of using a constraint on the element using FHIRPath, since constraints allow for the provision of a human readable message associated with the regex' (1 uses)
INFORMATION: StructureDefinition/Patient-twngs: StructureDefinition.snapshot.element[97].slicing.discriminator[0]: The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) (1 uses)
INFORMATION: StructureDefinition/ServiceRequest-twngs: StructureDefinition.snapshot.element[17].slicing.discriminator[0]: The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) (1 uses)
INFORMATION: StructureDefinition/ServiceRequest-twngs: StructureDefinition.snapshot.element[24].slicing.discriminator[0]: The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) (1 uses)
INFORMATION: ValueSet.where(id = 'nhi-organization'): The value set expansion is too large, and only a subset has been displayed (1 uses)
WARNING: ImplementationGuide/tw.nhri.ngs: ImplementationGuide.dependsOn[2]: The ImplementationGuide uses package tw.gov.mohw.twcore#0.3.2 released on 2024-12-12, but the most recent appropriate version is 1.0.0. This reference is getting old and the more recent version should be considered (1 uses)
WARNING: Observation/obs-biomarker-min: Observation: Best Practice Recommendation: In general, all observations should have a performer (1 uses)
WARNING: Observation/obs-cnv-min: Observation: Best Practice Recommendation: In general, all observations should have a performer (1 uses)
WARNING: Observation/obs-fusion-min: Observation: Best Practice Recommendation: In general, all observations should have a performer (1 uses)
WARNING: Observation/obs-geneinfo-min: Observation: Best Practice Recommendation: In general, all observations should have a performer (1 uses)
WARNING: Observation/obs-othvar-min: Observation: Best Practice Recommendation: In general, all observations should have a performer (1 uses)
WARNING: Observation/obs-variant-min: Observation: Best Practice Recommendation: In general, all observations should have a performer (1 uses)
WARNING: Organization/org-gene-min: Organization.identifier[0].system: No definition could be found for URL value 'https://dep.mohw.gov.tw' (1 uses)
WARNING: Patient/pat-min: Patient.identifier[0].system: No definition could be found for URL value 'http://www.moi.gov.tw' (1 uses)
WARNING: Patient/pat-min: Patient.identifier[1].system: No definition could be found for URL value 'https://tpech.gov.taipei' (1 uses)
WARNING: StructureDefinition/Composition-twngs: StructureDefinition.snapshot.element[37].binding.valueSet: There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-ActCode'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-ActCode' to 'http://terminology.hl7.org/ValueSet/v3-ActCode|3.0.0' (1 uses)
WARNING: StructureDefinition/DocumentReference-twngs: StructureDefinition.differential.element[4].example[0].value.ofType(url): No definition could be found for URL value 'file://PathologyReport01.pdf' (1 uses)
WARNING: StructureDefinition/DocumentReference-twngs: StructureDefinition.snapshot.element[38].example[1].value.ofType(url): No definition could be found for URL value 'file://PathologyReport01.pdf' (1 uses)
WARNING: StructureDefinition/DocumentReference-twngs: StructureDefinition.snapshot.element[49].binding.valueSet: There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-ActCode'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-ActCode' to 'http://terminology.hl7.org/ValueSet/v3-ActCode|3.0.0' (1 uses)
WARNING: StructureDefinition/Organization-gene-twngs: StructureDefinition.differential.element[1].example[0].value.ofType(uri): No definition could be found for URL value 'https://dep.mohw.gov.tw' (1 uses)
WARNING: StructureDefinition/Organization-gene-twngs: StructureDefinition.snapshot.element[14].example[1].value.ofType(uri): No definition could be found for URL value 'https://dep.mohw.gov.tw' (1 uses)
WARNING: StructureDefinition/Patient-twngs: StructureDefinition.snapshot.element[9].type[0].profile[0]: There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-nationality'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1 (from hl7.fhir.r4.core#4.0.1), 5.1.0 (from hl7.fhir.uv.extensions.r4#5.1.0), 5.2.0 (from hl7.fhir.uv.extensions.r4#5.2.0). Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-nationality' to 'http://hl7.org/fhir/StructureDefinition/patient-nationality|5.2.0' (1 uses)
WARNING: StructureDefinition/ServiceRequest-twngs: StructureDefinition.snapshot.element[43].binding.valueSet: There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-ServiceDeliveryLocationRoleType'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#5.0.0), 3.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-ServiceDeliveryLocationRoleType' to 'http://terminology.hl7.org/ValueSet/v3-ServiceDeliveryLocationRoleType|3.0.0' (1 uses)
WARNING: StructureDefinition/Specimen-twngs: StructureDefinition.snapshot.element[34].binding.valueSet: There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v2-0916'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#6.1.0), 3.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v2-0916' to 'http://terminology.hl7.org/ValueSet/v2-0916|3.0.0' (1 uses)
WARNING: StructureDefinition/Specimen-twngs: StructureDefinition.snapshot.element[52].binding.valueSet: There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v2-0371'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#6.1.0), 3.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v2-0371' to 'http://terminology.hl7.org/ValueSet/v2-0371|3.0.0' (1 uses)
WARNING: StructureDefinition/Specimen-twngs: StructureDefinition.snapshot.element[53].binding.valueSet: There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v2-0371'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#6.1.0), 3.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v2-0371' to 'http://terminology.hl7.org/ValueSet/v2-0371|3.0.0' (1 uses)
WARNING: StructureDefinition/Specimen-twngs: StructureDefinition.snapshot.element[54].binding.valueSet: There are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v2-0493'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.0.0', found versions: 2.0.0 (from hl7.terminology.r4#6.1.0), 3.0.0 (from hl7.terminology.r4#7.1.0). Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v2-0493' to 'http://terminology.hl7.org/ValueSet/v2-0493|3.0.0' (1 uses)